Tapez et nom du câble
| Superficie transversale nominale ㎡ | Isolation épaisseur mm | YJV YJY YJLV YJLY | YJV22 YJV22 YJLV23 YJLV2 3 | YIV32 YV32 YLV32 YILV32 | ||||||
| Environ dans l'ensemble diamètre mm | Poids calculé du câble | Environ dans l'ensemble diamètre mm | Poids calculé du câble | Environ dans l'ensemble diamètre mm | Poids calculé du câble | |||||
| YJV YJY | YJLV YJLY | YJV22 YJV22 | YJLV23 YJLV23 | YJLV23 YJLV23 | YJLV32 YJLV32 | |||||
| 1×25 | 3.4 | 19.2 | 560 | 一 | 23.2 | 839 | 25.2 | 935 | 一 | |
| 1×35 | 3.4 | 20.3 | 678 | 一 | 24.3 | 970 | 26.3 | 1069 | 一 | |
| 1×50 | 3.4 | 21.5 | 818 | 529 | 25.5 | 1127 | 838 | 27.5 | 1229 | 940 |
| 1×70 | 3.4 | 23.3 | 1056 | 637 | 27.1 | 1375 | 956 | 29.3 | 1495 | 1076 |
| 1×95 | 3.4 | 25.2 | 1342 | 762 | 29.0 | 1685 | 1105 | 31.2 | 1818 | 1238 |
| 1×120 | 3.4 | 26.4 | 1587 | 859 | 30.2 | 1946 | 1218 | 32.4 | 2081 | 1353 |
| 1×150 | 3.4 | 28.2 | 1887 | 988 | 32.0 | 2269 | 1370 | 34.2 | 2412 | 1513 |
| 1×185 | 3.4 | 29.8 | 2251 | 1130 | 33.6 | 2652 | 1531 | 35.8 | 2801 | 1680 |
| 1×240 | 3.4 | 32.4 | 2827 | 1359 | 37.6 | 3610 | 2142 | 38.4 | 3425 | 1957 |
| 1×300 | 3.4 | 34.9 | 3447 | 1602 | 39.9 | 4269 | 2424 | 40.9 | 4084 | 2239 |
| 1×400 | 3.4 | 37.6 | 4281 | 1916 | 42.8 | 5182 | 2817 | 44.6 | 5104 | 2739 |
| 1×500 | 3.4 | 41.1 | 5356 | 2320 | 46.7 | 6377 | 3341 | 48.1 | 6249 | 3213 |
| 1×630 | 3.4 | 45.0 | 6737 | 2828 | 50.8 | 7872 | 3963 | 54.6 | 8078 | 4169 |
| 1×800 | 3.4 | 49.1 | 8444 | 3441 | 55.1 | 9706 | 4703 | 57.7 | 9765 | 4762 |
| 1×1000 | 3.4 | 53.1 | 10243 | 4093 | 59.3 | 11630 | 5480 | 62.7 | 11795 | 5645 |
| 3×25 | 3.4 | 38.7 | 1859 | 一 | 44.6 | 2614 | 一 | 45.7 | 3479 | 一 |
| 3×35 | 3.4 | 41.3 | 2255 | — | 47.4 | 3067 | 一 | 48.3 | 3970 | 一 |
| 3×50 | 3.4 | 44.1 | 2719 | 1852 | 50.1 | 3569 | 2697 | 52.3 | 5021 | 4149 |
| 3×70 | 3.4 | 47.7 | 3454 | 2197 | 54.0 | 4392 | 3129 | 56.3 | 6002 | 4739 |
| 3×50 | 3.4 | 51.6 | 4330 | 2590 | 57.9 | 5338 | 3590 | 60.2 | 7045 | 5297 |
| 3×120 | 3.4 | 54.4 | 5140 | 2955 | 60.9 | 6197 | 4000 | 63.2 | 8017 | 5820 |
| 3×150 | 3.4 | 58.1 | 6055 | 3359 | 64.9 | 7238 | 4528 | 67.1 | 9130 | 6420 |
| 3×185 | 3.4 | 61.9 | 7271 | 3907 | 68.6 | 8453 | 5072 | 70.9 | 10515 | 7134 |
| 3×240 | 3.4 | 67.3 | 9050 | 4647 | 74.4 | 10388 | 5962 | 76.5 | 12566 | 8140 |
| 3×300 | 3.4 | 72.7 | 10993 | 5457 | 79.7 | 12419 | 6855 | 82.1 | 14825 | 9261 |
| 3×400 | 3.4 | 78.5 | 13589 | 6494 | 87.1 | 15975 | 8845 | 89.6 | 18802 | 11672 |
| 3×500 | 3.4 | 86.2 | 17026 | 7917 | 95.7 | 19720 | 10566 | 97.5 | 22745 | 13591 |
Tapez et nom du câble
| Nominal croix- en coupe surface mm2 | Isolation épaisseur mm | YJV YJY YJLV YJLY | YJV22 YJV22YJLV23 YJLV23 | YJV32 YJV32 YJLV32 YJLV32 | ||||||
| Environ dans l'ensemble diamètre mm | Calculé poids de câble | Environ dans l'ensemble diamètre mm | Calculé weight de câble | Environ dans l'ensemble diamètre mm | Calculé weight de câble | |||||
| YJV YJY | YJLV YJLY | YJV22 YJV22 | YJLV23 YJLV23 | YJLV23 YJLV23 | YJLV32 YJLV32 | |||||
| 1×25 | 4.5 | 21.4 | 639 | — | 25.4 | 947 | — | 27.4 | 1049 | — |
| 1×35 | 4.5 | 22.7 | 767 | — | 26.5 | 1080 | — | 28.7 | 1199 | — |
| 1×50 | 4.5 | 23.9 | 913 | 624 | 27.7 | 1241 | 952 | 29.9 | 1368 | 1079 |
| 1×70 | 4.5 | 25.7 | 1159 | 740 | 29.5 | 1510 | 1091 | 31.7 | 1644 | 1225 |
| 1×95 | 4.5 | 27.4 | 1440 | 860 | 31.4 | 1825 | 1245 | 33.4 | 1952 | 1372 |
| 1×120 | 4.5 | 28.8 | 1701 | 973 | 32.6 | 2092 | 1364 | 34.8 | 2235 | 1507 |
| 1×150 | 4.5 | 30.4 | 1995 | 1096 | 34.4 | 2419 | 1520 | 36.4 | 2554 | 1655 |
| 1×185 | 4.5 | 32.2 | 2377 | 1256 | 37.4 | 3156 | 2035 | 38.2 | 2968 | 1847 |
| 1×240 | 4.5 | 34.8 | 2964 | 1496 | 39.8 | 3783 | 2315 | 40.8 | 3600 | 2132 |
| 1×300 | 4.5 | 37.3 | 3594 | 1749 | 42.5 | 4488 | 2643 | 44.3 | 4406 | 2561 |
| 1×400 | 4.5 | 39.8 | 4420 | 2055 | 45.2 | 5392 | 3027 | 47.0 | 5304 | 2939 |
| 1×500 | 4.5 | 43.5 | 5526 | 2490 | 49.1 | 6604 | 3568 | 50.7 | 6481 | 3445 |
| 1×630 | 4.5 | 47.4 | 6921 | 3012 | 53.4 | 8139 | 4230 | 55.8 | 8166 | 4257 |
| 1×800 | 4.5 | 51.5 | 8643 | 3640 | 57.5 | 9963 | 4960 | 60.1 | 10015 | 5012 |
| 1×1000 | 4.5 | 55.3 | 10435 | 4285 | 61.5 | 11875 | 5725 | 64.1 | 11933 | 5783 |
| 3×25 | 4.5 | 43.9 | 2160 | — | 49.9 | 3024 | — | 51.1 | 4010 | — |
| 3×35 | 4.5 | 46.2 | 2551 | — | 52.3 | 3447 | — | 54.6 | 5003 | — |
| 3×50 | 4.5 | 49.0 | 3036 | 2164 | 55.3 | 3994 | 3122 | 57.6 | 5623 | 4751 |
| 3×70 | 4.5 | 52.9 | 3812 | 2549 | 59.4 | 4865 | 3602 | 61.5 | 6606 | 5343 |
| 3×50 | 4.5 | 56.8 | 4747 | 2999 | 63.2 | 5833 | 4085 | 65.6 | 7741 | 5993 |
| 3×120 | 4.5 | 59.6 | 5546 | 3349 | 66.2 | 6711 | 4514 | 68.6 | 8693 | 6496 |
| 3×150 | 4.5 | 63.2 | 6528 | 3818 | 70.1 | 7751 | 5041 | 72.2 | 9797 | 7087 |
| 3×185 | 4.5 | 66.9 | 7728 | 4347 | 73.7 | 8985 | 5604 | 76.1 | 11206 | 7825 |
| 3×240 | 4.5 | 72.4 | 9574 | 5148 | 79.5 | 10954 | 6528 | 81.8 | 13322 | 8896 |
| 3×300 | 4.5 | 77.8 | 11572 | 6008 | 86.5 | 13880 | 8316 | 88.7 | 16685 | 11121 |
| 3×400 | 4.5 | 83.6 | 14281 | 7151 | 92.5 | 16704 | 9574 | 94.7 | 19671 | 12541 |
| 3×500 | 4.5 | 91.1 | 17640 | 8486 | 100.8 | 20456 | 11302 | 102.8 | 23644 | 14490 |
Type/Nom Utilisation principale du câble en alliage d'aluminium série 8030 à haute conductivité
| Type | Nom | Principales utilisations |
| YJLHV | · Noyau en alliage d'aluminium réticulé polyvinyle isolé en polyéthylène câble d'alimentation à gaine de chlorure | · Il peut être posé dans un intérieur non humide, dans un tunnel et fixé sur le support, ce qui permet d'économiser le coût d'un pont ou d'un tuyau. |
| YJLHY | · Noyau en alliage d'aluminium réticulé polyéthylène isolant polyéthylène câble d'alimentation gainé | ·Il peut être posé dans un environnement sec ou humide, et le support intérieur, le support, l'échelle ou le support de câble peuvent être utilisés. La tranchée de câbles extérieure, canal par canal ou la pose directement enterrée, peut résister à une plus grande force mécanique externe. |
| YJLHV22 | · Noyau en alliage d'aluminium réticulé polyvinyle isolé en polyéthylène ruban d'acier à gaine extérieure en chlorure câble d'alimentation blindé | ·Des performances stables et fiables, légères, peuvent être posées à l'intérieur, avec des supports fixes, posées dans des tunnels, des pipelines, des tranchées de câbles et des sols meubles, ne peuvent pas résister à l'action mécanique externe. |
| YJLHY23 | · Noyau en alliage d'aluminium réticulé ruban d'acier isolé en polyéthylène blindage extérieur en polyéthylène câble d'alimentation gainé | ·Des performances stables et fiables, peuvent être directement enterrées, peuvent résister à une certaine force mécanique externe, mais ne peuvent pas résister à une tension importante. |
| YJLHV32 | · Noyau en alliage d'aluminium réticulé fil fin isolé en polyéthylène blindage extérieur en polychlorure de vinyle câble d'alimentation gainé | · Il peut être posé dans un environnement sec ou humide, et le support intérieur, le support, l'échelle ou le câble de fixation peuvent être utilisés. L'extérieur peut utiliser une tranchée de câbles, un tunnel ou une pose enterrée directe, peut résister à une plus grande force mécanique externe. |
| YJLHY33 | · Noyau en alliage d'aluminium réticulé fil fin isolé en polyéthylène extérieur en polyéthylène blindé câble d'alimentation gainé | · Léger, peut être posé dans un environnement sec ou humide, à l'intérieur peut être utilisé comme support, support, échelle ou surface de fixation de câble ; L'extérieur peut utiliser une tranchée de câbles, un tunnel ou une pose enterrée directe, peut résister à une plus grande force mécanique externe. Avec un excellent retardateur de flamme et une excellente résistance au feu, sont jusqu'à la classe A. |
Remarque : selon les exigences du client, la production de câbles ignifuges de qualité A, ignifuges de qualité B, ignifuges de qualité C ou en alliage d'aluminium, modèle de câble avant d'ajouter « ZA-, ZB- ou ZC(ZR) - » ; Tels que ZA-YJLHV, ZB-YJLHV22, ZC-YJLHY. Toutes sortes de câbles en alliage d'aluminium ignifuges à faible émission de fumée sans halogène, en ajoutant « WDZA -, WDZB - ou WDZR(ZC) - » avant le modèle de câble. Si le câble en alliage d'aluminium avec une résistance à basse température de -40 ℃ est utilisé dans des zones à température ambiante très basse, ajoutez "(-40)" après le modèle de produit.
L